Topaz 100
Ultra-Isolator
Noise Suppression
Isolation Transformer
Installation and User Manual
www.mgeups.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1 - Topaz 100

Topaz 100Ultra-IsolatorNoise SuppressionIsolation TransformerInstallation and User Manualwww.mgeups.com

Strona 2 - IMPORTANT SAFETY INSTRUCTIONS

1.3.1 Location and StorageThe unit is convection cooled with the air vents located on the sides and top of the unit enclosure. Therefore, itshould be

Strona 3

Introductionpage 1 — 3Installation and User Manual1.4 Prerequisites to InstallationAn efficient installation depends on careful planning and site prep

Strona 4

1.5.3 Mechanical SpecificationsRating Input plug Output receptacles (NEMA)125 VA – 1 kVA 5-15P 5-20R21.8 kVA L5-20P 2 x 5-20R22.4 kVA L5-30P 2 x 5-2

Strona 5

Introductionpage 1 — 5Installation and User ManualFigure 1-2: 125VA-1kVA Isolation Transformer Enclosure.Figure 1-3: 125VA-1.0kVA Isolation Transfo

Strona 6

Figure 1-4: 1.8kVA Isolation Transformer Enclosure.Figure 1-5: 2.4 kVA Isolation Transformer Enclosure.IntroductionTopaz 100 Ultra-Isolator Transfo

Strona 7 - Contents

Introductionpage 1 — 7Installation and User ManualFigure 1-6: 1.8 kVA-7.5 kVA Isolation Transformer Hardwired Enclosure.SPECIFICATION TAG.50" (

Strona 8

(This page left blank intentionally)Topaz 100 Ultra-Isolator Transformerpage 1 — 8

Strona 9

2.0 ScopeThis section guides the User through installation requirements, circuit wiring diagrams, hardwired connections, andfactory input/output confi

Strona 10

In order to access this fuse and configure the Topaz 100 input for 240VAC, the units cover must be removed. Thisis accomplished by removing the (6) s

Strona 11 - Installation and User Manual

Installationpage 2 — 3Installation and User ManualFigure 2-1: Wiring Diagram for 125VA-1000VA 120VAC Input.Figure 2-2: Wiring Diagram for 1800VA-240

Strona 12 - Introduction

IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS – This manual contains important instructions for the Topaz 100 that must befollowed during opera

Strona 13

Figure 2-3: Circuit Diagram for 125VA-1000VA 240/120VAC Input.InstallationTopaz 100 Ultra-Isolator Transformerpage 2 — 4X1X3X2X4GH1H1-AH3H2H4H1H1-AH3

Strona 14

Installationpage 2 — 5Installation and User ManualFigure 2-4: Circuit Diagram for 1800VA-7500VA 240/120VAC Input.X1X3X2X4GH1H3H2H4H1H3H2H4X1X3X2X4G24

Strona 15

(This page left blank intentionally)Topaz 100 Ultra-Isolator Transformerpage 2 — 6

Strona 16

3.0 ScopeThis section contains preventive maintenance for the Topaz 100 units, and troubleshooting to assist the User withany communication and config

Strona 17 - Installation

(This page left blank intentionally)Topaz 100 Ultra-Isolator Transformerpage 3 —2

Strona 18

Symbols Definition / Meaning@ At./ And/or.+/- Plus or Minus.≤ Equal to or less than.# Number.°C Degree Celsius.°F Degree Fahrenheit.Ø Phase angle.Ω Oh

Strona 19

Current rating The maximum current that a conductor or equipment can carry reliably without damage.dBA Decibel Adjusted.dBrnC Decibel above reference

Strona 20

NNeutral.NC Normally close.NO Normally open.NEC National Electrical Code.NFPA National Fire Protection Association.NO. or No. Part number.On-line mode

Strona 21

(This page left blank intentionally)Topaz 100 Ultra-Isolator Transformerpage g — 4

Strona 22

Reorder Form1660 Scenic AvenueCosta Mesa, CA 92626Use this form to report any errors, omissions, or other problems you have experienced, or toorder a

Strona 23

Topaz 100Ultra-IsolatorNoise SuppressionIsolation TransformerInstallation and User ManualFor service call1-800-523-014286-109608-00 C01 09/03Copyr

Strona 26

1660 Scenic Avenue, Costa Mesa, California 92626 • (714) 557-1636www.mgeups.com

Strona 27

Topaz 100 Ultra-Isolator Transformerpage ivTopaz 100Installation and User ManualMGE Warranty InformationWarrantyThe liability of MGE UPS SYSTEMS, Inc.

Strona 28

How to Use This Manualpage vInstallation and User ManualHow To Use This ManualThis manual is designed for ease of use and easy location of information

Strona 29 - 1660 Scenic Avenue

Topaz 100 Ultra-Isolator Transformerpage viCAUTION: Record All ///serial Numberspage viCAUTIONRECORD ALL SERIAL NUMBERS FOR THE TOPAZ100. THESE SERIAL

Strona 30

page c iInstallation and User ManualContentssection description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page

Strona 31

Figuresfigure description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page1-1 Vertical Mounting Draw

Strona 32

1.0 ScopeThis section is a general description of the Topaz 100 Ultra-Isolator. Includes receiving, electrical, environmental,mechanical specificatio